TM 5-5420-209-34
2-10. Boom Assembly.
This task covers:
Repair
INITIAL SETUP
Tools
General Mechanics TooI Kit
(NSN 5180-00-177-7033)
Materials/Parts
Solvent, Dry Cleaning (Item 2, Appendix B)
Rags, Wiping (Item 5, Appendix B)
Equipment Condition:
Boom assembly removed
(TM 5-5420-209-12).
a Repair. (figure 2-3)
WARNING
Dry cleaning solvent, PD-680, used to dean parts is potentially dangerous to personnel and
property. Avoid repeated and prolonged skin contact. Do not use near open flame or exces-
sive heat. Flash point of solvent is 100°F-138°F (38°C-60°C).
(1) Clean boom assembly (1) using dry cleaning solvent and dry thoroughly.
(2) Inspect boom assembly (1) for cracks and repair by welding in accordance with TM 9-237.
2-14