TM 5-5420-209-34
2-11. Ramp Bay Bow Pontons.
This task covers:
Repair
INITIAL SETUP
Tools
Equipment Condition:
General Mechanics Tool Kit
Ramp bay bow ponton removed
(NSN 5180-00-177-7033)
(TM 5-5420-209-12).
Materials/Parts
Compound, Covering (Item 1, Appendix B)
Solvent, Dry Cleaning (Item 2, Appendix B)
Rags, Wiping (Item 5, Appendix B)
a. Repair. (figure 2-4)
WARNING
Dry cleaning solvent, PD-680, used to dean parts is potentially dangerous to prsonnel and
property. Avoid repeated and prolonged skin contact. Do not use near open flame or exces-
sive heat. Flash point of solvent is 100°F - 138°F (38°C -60°C).
(1)
(2)
(3)
(4)
(5)
(6)
(7)
(8)
(9)
(lo)
(11)
(12)
Clean bow pontons using dry cleaning solvent and dry thoroughly.
Raise lever on snap-tite plug (1) and remove plug.
Remove screw (2) securing chain (3) and remove chain.
Install ponton leak detector into bow ponton (4).
Connect air source to leak detector and pressurize ponton to 1.5 ± 0.1 psig.
Apply soapy solution to ponton surfaces and check for leaks.
Inspect plates and roadway decking for dents, and repair dents in accordance with TM 9-450.
Inspect plates and check for cracks and repair cracks in accordance with TM 9-237.
Inspect surfaces for damage or minor gouging or plate, bore, or structural angle distortion and
repair with a file or suitable bending tool.
After repair of surface damage, dean, treat and paint the repaired area in accordance with
MIL-T-704, Type B.
Remove ponton leak detector.
Mask off cavities and bores in interior bow ponton and apply nonslip deck covering compound
to the top surface of ponton decking and to top surface of outboard sheeting.
2-16