TM 5-5420-226-20-3
GENERATOR AIR INTAKE TUBE ASSEMBLY REPLACEMENT (Sheet 2 of 3)
3.
Using socket, remove two bolts (F), lockwashers (G), and flat washers (H).
4.
Cleaning agent specified is flammable. Use only in well ventilated areas. Keep away from
flame, sparks, or heat. Do not smoke while using. Prevent contact with eyes, mouth, and/or
skin. Wear rubber gloves when performing cleaning procedures.
1. Using alcohol and rags clean hose. Inspect for cracks and breaks.
2. Using dry cleaning solvent, clean tube and mounting hardware.
3. Using rags, wipe tube and mounting hardware. Inspect for bends, breaks, and cracks.
Replace parts as required if defective.
TA168655
Go on to Sheet 3
10-4