TM 5-5420-226-20-3
ENGINE GENERATOR REPLACEMENT (Sheet 1 of 2) (650 AMP GENERATOR)
PROCEDURE INDEX
PROCEDURE
PAGE
Removal
Installation
TOOLS:
1/2-inch open and closed end wrench
3/4-inch open and closed end wrench
9/16-inch open and closed end wrench
13/16-inch open and closed end wrench
15/16-inch open and closed end wrench
12-inch adjustable wrench
Pliers, slip joint
SPECIAL TOOLS:
Ground hop kit (Item 31, Chapter 3, Section I)
Box wrench (Item 4, Chapter 3, Section I)
SUPPLIES:
Silicone compound (Item 32, Appendix D)
Two wooden blocks
Drain pan
Preformed packing
Locknuts
Rags (Item 65, Appendix D)
PERSONNEL:
Two
PRELIMINARY PROCEDURE:
WARNING
Generator weighs approximately 125 pounds. Injury to personnel or damage to equipment could result through
careless handling.
A
REMOVAL:
1. Place two wooden blocks under generator (A).
2.
Using 3/4-inch wrench remove electrical leads (B, C).
3.
Using 15/16-inch wrench remove oil inlet hose (D)
and drain oil into suitable drain pan.
B
D
C
Change 6