FUEL SHUTOFF AND PERSONNEL HEATER CIRCUIT BREAKERS REPLACEMENT
HEU ENGINE ACCESSORY RELAY REPLACEMENT

M48A5 Tank Chassis, Transporting: For Bridge, Armored-Vehicle-Launched; Scissoring Type, Class 60 -3 Page Navigation
  163    164    165    166    167  168  169    170    171    172    173  
img
TM 5-5420-226-20-3
FUEL SHUTOFF AND PERSONNEL HEATER CIRCUIT BREAKERS REPLACEMENT (Sheet 2 of 2)
INSTALLATION:
Position circuit breaker(A) to mounting plate (B).
1.
Using screwdriver, install two screws (C) and lockwashers (D) securing circuit
2.
breaker (A) to mounting plate (B).
3.
Install electrical leads (E) to circuit breaker (A) by pushing in.
4.
Install access plate at comm-
ander's , station (page 17-9).
End of Task
TA168816
10-166


Privacy Statement