TM 5-5420-226-20-3
UNIVERSAL JOINT REPLACEMENT (Sheet 6 of 7)
NOTE
It may be necessary to use pry
bar to wedge the univesal joint
to prevent it from turning bile
tightening screw (E).
11. Using 13/1 6 inch socket, tighten four screws (E).
12. Using torque wrench, tighten four screws
(E) to 110-130 lb-ft (146-173 Nm).
13.
Using slip joint pliers, install locking
wire (G) to each two adjacent screws (E)
(page C-28).
Using rope, have second technician,
14.
aline universal joint with final drive
adapter (H).
15.
Using pinch bar, pry final drive adapter (H)
away from final drive (A) into universal
joint (B) (each side).
TA169126
Go on to Sheet 7
12-20