TM 5-5420-227-24
Preventive Maintenance Checks and Services for M48A5 AVLB Launcher
Location
Not Fully Mission
Procedure
Interval
Item to
Item
Capable if:
Check/Service
No.
WARNING
FRH hydraulic fluid may contain tricresyl phosphate which, if taken
internally, can produce paralysis. Hydraulic fluid may be absorbed
through the skin. Wear long sleeves, gloves, goggles, and faceshield. If
FRH gets in eyes, wash them immediately and get medical aid
immediately. If FRH gets on skin, thoroughly wash with soap and
water. Wash hands thoroughly prior to eating or smoking. Application
of these measures is considered an effective control of the hazard.
1
Perform hydraulic fluid sampling
Semiannual
Reservoir
IAW DA PAM 738-750.
ARMY OIL ANALYSIS PROGRAM
(AOAP).
FRH hydraulic fluid samples from
the launcher system must be submit-
ted to an assigned AOAP laboratory
semiannually or every 25 hours of
operation whichever occurs first, in
accordance with DA PAM 738-750.
FRH hydraulic fluid will be analyzed
for condition and will be changed
only when directed by the AOAP
laboratory. In the event AOAP labo-
ratory support is not available, drain
FRH hydraulic fluid annually. Annu-
al hydraulic fluid changes are to be
coordinated with seasonal changes.
2
Reservoir
On
Fill hydraulic reservoir (TM 5-5420-
Condition
226-10). Operate hydraulic system for
Change
2
2-9