HYDRAULIC FLUID FILTER ASSEMBLY REPAIR (Sheet 5 of 8)
CLEANING AND INSPECTION:
Cleaning agent specified is flammable. Use only in well ventilated areas. Keep away
from flames, sparks, or heat. Do not smoke while using. Prevent contact with eyes,
mouth, and/or skin. Wear rubber gloves when performing cleaning procedures.
Using rags and dry cleaning solvent, clean all parts.
1.
2.
Replace all defective parts.
3.
ASSEMBLY:
Manually install wiper ring (A) on piston (B).
1.
Manually install piston (B) in housing (C) as
2.
far as possible.
Manually install two springs (D) on piston stud
3.
Manually install preformed packing (F) on
4.
cover (G).
Position cover (G) on housing (C).
5.
6.
and screws (J) securing cover (G) to
housing (C).
Go on to Sheet 6