TM 5-5420-227-24
RESERV OI R QU ADRAN T BLOWER M OT OR REPAI R (She e t 2 of 4 )
6.
Using screwdriver, remove four screws (L) and lockwashers (M). Throw lockwashers (M)
away.
7.
Manually separate commutator head (H), fan head (J), frame (K), two gaskets (N), armature
(P), two bearings (0), and seal assembly (R). Throw gaskets (N) and seal assembly (R) away.
Using screwdriver, remove five screws (S) and lockwashers (T). Throw lockwashers (T)
8.
away.
Manually remove capacitor (U) and cable assembly (V).
9.
10.
Using screwdriver, remove four screws (W).
Manually remove receptacle assembly (X) and gasket (Y). Throw gasket (Y) away.
11.
12.
Using adjustable wrench, remove pipe plug (Z).
CLEANING AND INSPECTION:
WARN I N G
Cle a ning a ge nt spe c ifie d is fla m m a ble . U se only in w e ll ve nt ila t e d a re a s. K e e p a w a y
from fla m e s, spa rk s, or he a t . Do not sm ok e w hile using. Pre ve nt c ont a c t w it h e ye s,
m out h, a nd/or sk in. We a r rubbe r glove s w he n pe rform ing c le a ning proc e dure s.
Clean all metallic parts with rags and solvent.
1.
2.
Inspect all parts for damage or wear.
Replace all unserviceable parts.
3.
TA170484
Go on to Sheet 3
4-5