Table 1. Operator Preventive Maintenance Checks and Services (PMCS)
for Interior Bay (Contd).
ITEM TO
NOT FULLY
ITEM
CHECK/
MISSION
NO.
INTERVAL
SERVICE
PROCEDURE
CAPABLE IF:
TM 5-5420-278-10
0016 00
0016 00-16
NOTE
If a hole is observed, monitor
the bridge or rafts
performance. If visual evidence
of taking on water is observed
(such as riding low in the
water), pump the water out
while operations continue. If
the water intake is faster than
the pumping capacity, remove
and replace the damaged bay.
The damaged bay is deadlined
until repairs are made.
31
During
Right outer
ponton lock (1)
at end of bay
Check for engagement.
Outer ponton lock
will not engage.
32
During
Right and inner
ponton bilge
plugs (2)
Ensure bilge plugs are secured and
not cracked or broken.
Any bilge plug
missing, cracked, or
broken.
1