TM 5-5420-278-100068 000068 00-2CABLE ASSEMBLY SERVICE (Contd)WARNING Skysol-100 mixture is combustible. Use mechanicalventilation whenever product is used in a confinedspace, is heated above ambient temperatures, or isagitated. DO NOT use or store near heat, sparks,flame, or other ignition sources. Keep container sealedwhen not in use.Contact with Skysol-100 may cause skin irritation. Usechemical-resistant gloves. In case of skin contact,remove any contaminated clothing and wash skinthoroughly with soap and water. Wash contaminatedclothing before reuse. Eye contact may cause irritation,tearing, or blurring of vision. Use face shield or goggleswhen eye contact may occur. In case of eye contact,flush eyes with large amounts of water for at leastfifteen (15) minutes or until irritation subsides.Inhalation may cause irritation to upper respiratorypassages. DO NOT have food or drink in the vicinity.1.Using clean rags and solvent, clean two cables (3), turnbuckles (4), springs(6), levers (5), cotter pins (2), and pins (1).2.Using clean rags, wipe dry both cable assemblies.NOTEEnsure cable assemblies are clean and dry prior toapplying oil and lubricant.3.Apply lubricant to two cables (3) (Item 6, WP 0072 00). Coat cables (3)thoroughly, then remove excess with clean rags.4.Apply lubricating oil to two pins (1) and threads of turnbuckles (4) (Item 5, WP 0072 00). Remove excess with clean rags.
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business