TM 5-5420-278-10
0068 00
0068 00-2
CABLE ASSEMBLY SERVICE (Contd)
WARNING
Skysol-100 mixture is combustible. Use mechanical
ventilation whenever product is used in a confined
space, is heated above ambient temperatures, or is
agitated. DO NOT use or store near heat, sparks,
flame, or other ignition sources. Keep container sealed
when not in use.
Contact with Skysol-100 may cause skin irritation. Use
chemical-resistant gloves. In case of skin contact,
remove any contaminated clothing and wash skin
thoroughly with soap and water. Wash contaminated
clothing before reuse. Eye contact may cause irritation,
tearing, or blurring of vision. Use face shield or goggles
when eye contact may occur. In case of eye contact,
flush eyes with large amounts of water for at least
fifteen (15) minutes or until irritation subsides.
Inhalation may cause irritation to upper respiratory
passages. DO NOT have food or drink in the vicinity.
1.
Using clean rags and solvent, clean two cables (3), turnbuckles (4), springs
(6), levers (5), cotter pins (2), and pins (1).
2.
Using clean rags, wipe dry both cable assemblies.
NOTE
Ensure cable assemblies are clean and dry prior to
applying oil and lubricant.
3.
Apply lubricant to two cables (3) (Item 6, WP 0072 00). Coat cables (3)
thoroughly, then remove excess with clean rags.
4.
Apply lubricating oil to two pins (1) and threads of turnbuckles (4)
(Item 5, WP 0072 00). Remove excess with clean rags.