TM 5-5420-278-24&P
0018 00
0018 00-24
Table 1. Unit Preventive Maintenance Checks and Services for Ramp Bay (Contd).
ITEM TO
ITEM
CHECK/
EQUIPMENT NOT
NO.
INTERVAL
SERVICE
PROCEDURE
READY/AVAILABLE IF:
1
2
3
RIGHT PUMP SHOWN
NOTE
PMCS for right and left fluid
pump assemblies is the same.
Right pump is shown.
40
Semi-
Right fluid
annually
pump cover (1),
pump (3), and
hoses (2)
a. Inspect for structural damage.
b. Inspect pump for proper fluid level and
leaks. Fill as required.
c. Inspect pump for proper operation.
d. Inspect all hoses for leaks.
e. Ensure direction lever and air vent
function properly.
a. Pump cover is
missing.
b. Any Class III
fluid leak is noted.
c. Pump is not
operational.
d. Any Class III
fluid leak is noted.
e. Vent or lever does
not function
properly.
41
Semi-
Left fluid
annually
pump cover (1),
pump (3), and
hoses (2)
a. Inspect for structural damage.
b. Inspect pump for proper fluid level and
leaks. Fill as required.
c. Inspect pump for proper operation.
d. Inspect all hoses for leaks.
e. Ensure direction lever and air vent
function properly.
a. Pump cover is
missing.
b. Any Class III
fluid leak is noted.
c. Pump is not
operational.
d. Any Class III
fluid leak is noted.
e. Vent or lever does
not function
properly.