TM-5-5420-279-10
3.14.6.8
Make sure the hydraulic cylinders fully retract for convenient attachment of the wire
stabilizer deployment strop.
3.14.6.9
Remove the crane stabilizer spreader pads from beneath the crane stabilizer legs.
Crane Leg Deployment, Wire Rope Pin Arrangement
3.14.6.10 Remove the retaining clip (8) and the pin (7) from the wire rope (6) attachment bracket on
each crane stabilizer leg (1).
3.14.6.11 Put wire rope (6) in position and re-insert the pin (7). Secure the pin (7) with the retaining
clip (4).
3.14.6.12 Remove the retaining clips (10, 11) and the locking pin (12) from the pivot of the crane
stabilizer leg (1).
3.14.6.13 Make sure the area around the crane stabilizer legs is clear of personnel. Operate the
crane stabilizer control (3) adjacent to the stabilizers to extend the stabilizers, rotating
both crane stabilizer legs to the vertical position movement (A).
3.14.6.14 Make sure the hydraulic cylinders extend and rotate the crane stabilizer legs to a vertical
inverted position.
NOTE
Extension of the hydraulic cylinders causes the legs to rotate upwards due to the attachment
geometry of the wire stabilizer deployment strops.
3.14.6.15 Install the locking pins and clips (12) in the pivot points of the crane stabilizer legs.
Secure the locking pins with the retaining clips (10,11).
3-115