TM 5-5420-280-10
0007 00
PALLET CONTROLS AND INDICATORS (Contd)
F
PALLET HYDRAULIC PUMP BYPASS VALVE LEVER -- Prior to
starting LPU, determine weight of oil in pallet hydraulic system and its
ambient temperature range. Refer to WP 0025 00. To operate, turn lever to
open bypass valve; lever should point down. Once LPU engine is running,
close bypass valve; lever should point to left. The bypass valve should remain
open when operating pallet hydraulic system off CBT hydraulic pump.
F
BYPASS VALVE
LPU HYDRAULIC PUMP
BYPASS VALVE LEVER, CLOSED POSITION SHOWN
G
TRANSFER VALVE LEVER -- Prior to transferring residual hydraulic oil
from CBT hydraulic reservoir to pallet reservoir, turn lever to close transfer
valve; lever should point the left. To open transfer valve, turn lever until
pointing up. The transfer valve must be in closed position prior to operating
LPU or CBT for normal operation of pallet hydraulic system.
G
TRANSFER VALVE
TRANSFER VALVE LEVER, CLOSED POSITION SHOWN
0007 00-3