TM 5-5420-280-10
0038 00
Pallet Electrical Troubleshooting (Contd)
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
29. RCU WILL NOT UNCOIL WINCH WIRE ROPE (R4-A+H+M)
Step 1. Check that KY1 and KY2 hydraulic control valve solenoid LED
lights are lit when action button 2 is depressed.
If both lights are lit on control valve solenoids, notify field
maintenance.
Step 2. Check to see if one or more control valve solenoid LED lights are out
when action button 2 is depressed.
If light is out, notify field maintenance.
END OF TESTING
30.
RCU WILL NOT LOWER LAUNCH BOOM TO RETRIEVAL POSITION (R4-A+H+M)
Step 1. Check that KY1 and KY18 hydraulic control valve solenoid LED
lights are lit when action button 2 is depressed.
If both lights are lit on control valve solenoids, notify field
maintenance.
Step 2. Check to see if one or more control valve solenoid LED lights are out
when action button 2 is depressed.
If light is out, notify field maintenance.
END OF TESTING
31. RCU WILL NOT RAISE NEAR-SHORE END OF BRIDGE WITH WINCH WIRE ROPE
(R5-H)
Step 1. Check that KY1 and KY21 hydraulic control valve solenoid LED
lights are lit when action button 2 is depressed.
If all lights are lit on control valve solenoids, notify field
maintenance.
Step 2. Check to see if one or more control valve solenoid LED lights are out
when action button 2 is depressed.
Step 3. Check for loose winch relays AD2, AD3, and AD4, located in
electrical box.
If light is out, notify field maintenance.
END OF TESTING