TM 5-5420-280-23&P
0108 00
ENGINE OIL BATH AIR CLEANER AND ADAPTER FLANGES MAINTENANCE (Contd)
REMOVAL
1.
Support air cleaner base (12) and unlock two clips (13) from base (12) and air cleaner housing (10).
2.
Remove base (12) and O-ring seal (11) from housing (10). Discard O-ring seal (11).
3.
Loosen screw (15) and remove dust cap (14) from inlet tube (16) on housing (10).
4.
Remove four screws (3), lockwashers (4), housing (10), and gasket (5) from adapter flange (1) and
mounting bracket (8). Discard lockwashers (4) and gasket (5).
5.
Loosen two clamps (2) on hose (7) and two adapter flanges (1).
6.
Remove four screws (3), lockwashers (4), adapter flange (1), and gasket (5) from intake manifold (6).
Discard lockwashers (4) and gasket (5).
7.
Remove two adapter flanges (1), clamps (2), hose (7), and gasket (5) from between mounting bracket
(8) and intake manifold (6). Discard gasket (5).
CLEANING AND INSPECTION
WARNING
Skysol 100 mixture is combustible. Use mechanical ventilation
whenever product is used in a confined space, is heated above
ambient temperatures, or is agitated. DO NOT use or store near
heat, sparks, flame, or other ignition sources. Keep container sealed
when not in use.
Contact with Skysol 100 may cause skin irritation. Use chemical-
resistant gloves. In case of skin contact, remove any contaminated
clothing and wash skin thoroughly with soap and water. wash
contaminated clothing before reuse. Eye contact may cause
irritation, tearing, or blurring of vision. Use face shield or goggles
when eye contact may occur. In case of eye contact, flush eyes with
large amounts of water for at least fifteen (15) minutes or until
irritation subsides. Inhalation may cause irritation to upper
respiratory passages. DO NOT have food or drink in the vicinity.
Failure to comply may result in injury to personnel.
1.
Clean all parts with Skysol 100 and dry with cloth before inspection.
2.
Inspect filter packing (17) for uneven sealing surface. Replace if uneven.
3.
Inspect filter packing (17) for missing filter wool. Replace if wool is missing.
4.
Inspect filter housing (10) for cracks. Replace if cracked.
5.
Inspect weld nuts (9) for damaged or worn threads. Replace if damaged or worn.
INSTALLATION
1.
Install two clamps (2), hose (7), two new gaskets (5), and adapter flanges (1) between intake
manifold (6) and mounting bracket (8).
2.
Align holes in adapter flange (1), gasket (5), and intake manifold (6) and install four new
lockwashers (4) and screws (3).
3.
Position new gasket (5) and housing (10) on mounting bracket (8), align holes in two gaskets (5),
mounting bracket (8), and weld nuts (9) on housing (10), and install four new lockwashers (4) and
screws (3).
4.
Tighten two clamps (2).
0108 00-2