TM 5-5420-280-23&P
0008 00
Electrical System Troubleshooting (Contd).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
10. RCU WILL NOT RAISE SECONDARY BOOM (L9-H)
Step 1. Check that KY1 and KY14 hydraulic control valve solenoid LED lights are lit when action
button 1 is depressed.
a. If both lights are lit on control valve solenoids, refer to malfunction 11 Hydraulic System
b. Check operation of IQAN-XP and IQAN-XS LED lights. Refer to WP 0004 00 step h.
Step 2. Check to see if only one of the control valve solenoid LED lights is lit.
a. If only one light is lit, check for 24 volts at control valve solenoid with light off.
b. If connector has 24 volts, replace control valve solenoid or hydraulic control valve. Refer
c. If connector has no voltage, check wires at KL-1 buss bar pin 1 for KY1 control valve
solenoid and KL-1 buss bar pin 14 for KY14 control valve solenoid. Refer to Electrical
d. Check wire between KL-1 buss bar pin 1 and IQAN-XS connector pin 20. Replace wire if
e. Check wire between KL-1 buss bar pin 14 and IQAN-XP connector pin 32. Replace wire if
END OF TESTING
11. RCU WILL NOT MOVE LOWER BRIDGE HALF INTO COUPLING POSITION (L10-A)
Step 1. Check that KY1 and KY6 hydraulic control valve solenoid LED lights are lit when action
button 1 is depressed.
NOTE
Limit switch KA4 stops lower bridge half at coupling position.
a. If all lights are lit on control valve solenoids, check limit switch KA4 to see if damaged or
out of adjustment. Adjust or replace limit switch KA4. Refer to WP 0056 00.
b. If limit switch KA4 is operating and control valve solenoid lights are lit, refer to
c. Check operation of IQAN-XP and IQAN-XS LED lights. Refer to WP 0004 00 step h.
Step 2. Check to see if one or more control valve solenoid LED lights are out when action button 1
is depressed.
a. If light is out, check for 24 volts at control valve solenoids.
b. If connector has 24 volts, replace control valve solenoid or hydraulic control valve. Refer
c. If connector has no voltage, check wires at KL-1 buss bar pin 1 for KY1 control valve
solenoid, KL-1 buss bar pin 6 for KY6 control valve solenoid, and KL-1 buss bar pin 28
for KA4 limit switch. Refer to Electrical System Schematic (WP 0122 00) and repair or
d. Check wire between KL-1 buss bar pin 1 and IQAN-XS connector pin 20. Replace wire if
e. Check wires between KL-1 buss bar pins 6 and 28 and IQAN-XP connector pins 25 and 5.
END OF TESTING
Change 1