• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
Electrical System Troubleshooting - Continued
Electrical System Troubleshooting - Continued

Special Tools List For Rapidly Emplaced Bridge (Reb) Page Navigation
  95    96    97    98    99  100  101    102    103    104    105  
img
. . . . . . . . . . . . . . . .
TM 5-5420-280-23&P
0008 00
Electrical System Troubleshooting (Contd).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
22. RCU WILL NOT LOWER NEAR-SHORE END OF BRIDGE (L18-H) (Contd)
Step 5. Check that KY1 and KY21 hydraulic control valve solenoid LED lights are lit when action
button 1 is depressed.
a. If all lights are lit on control valve solenoids, refer to malfunction 5 in Hydraulic System
Troubleshooting (WP 0010 00).
b. Check operation of IQAN-XP and IQAN-XS LED lights. Refer to WP 0004 00 step h.
Step 6. Check to see if one or more control valve solenoid LED lights are out when action button 1
is depressed.
a. If light is out, check for 24 volts at control valve solenoid.
b. If connector has 24 volts, replace control valve solenoid or hydraulic control valve. Refer
to WP 0075 00.
c. If connector has no voltage, check wires at KL-1 buss bar pin 1 for KY1 control valve
solenoid and KL-1 buss bar pin 21 for KY21 control valve solenoid. Refer to Electrical
System Schematic (WP 0122 00) and repair or replace wires (WP 0053 00).
d. Check wire between KL-1 buss bar pins 1 and 21 and IQAN-XS connector pins 20 and 36.
Replace wires if damaged. Refer to WP 0053 00.
e. Check wire between KL-1 buss bar pin 2 and IQAN-XP connector pin 37. Replace wire if
damaged. Refer to WP 0053 00.
END OF TESTING
23. RCU WILL NOT RAISE LAUNCH BOOM TO TRAVEL POSITION (L20-H)
Step 1. Check that KY1 and KY19 hydraulic control valve solenoid LED lights are lit when action
button 1 is depressed.
NOTE
Potentiometer JR2 is used to stop launch boom at a set position in
the launching procedures.
a. If both lights are lit on control valve solenoids, check potentiometer JR2 position 1 to see
if damaged or out of adjustment. Adjust or replace potentiometer JR2. Refer to
WP 0093 00.
b. If potentiometer JR2 is operating and control valve solenoid lights are lit, refer to
malfunction 7 in Hydraulic System Troubleshooting (WP 0010 00).
c. Check operation of IQAN-XP and IQAN-XS LED lights. Refer to WP 0004 00 step h.
Step 2. Check to see if one or more control valve solenoid LED lights are out when action button 1
is depressed.
a. If light is out, check for 24 volts at control valve solenoid.
b. If connector has 24 volts, replace control valve solenoid or hydraulic control valve. Refer
to WP 0075 00.
c. If connector has no voltage, check wires at KL-1 buss bar pin 1 for KY1 control valve
solenoid, KL-1 buss bar pin 19 for KY19 control valve solenoid, and KL-1 buss bar
pins 34, 35, and 48 for JR2 potentiometer. Refer to Electrical System Schematic (WP 0122
00) and repair or replace wires (WP 0053 00).
d. Check wire between KL-1 buss bar pin 1 and IQAN-XS connector pins 20. Replace wire if
damaged. Refer to WP 0053 00.
e. Check wires between KL-1 buss bar pins 19, 34, 35, and 48 and IQAN-XP connector pins
36, 15, 17, and 1. Replace wires if damaged. Refer to WP 0053 00.
END OF TESTING