TM 55-1945-205-10-2
0029 00 2
0029 00
127(
Operation of the electric (24VDC) fuel pump is preset to automatically transfer fuel from the
base tank to the day tank with the generator control panel master switch.
c.
Running the generator with the master switch in the PRIME & RUN position (3) will not automatically refuel
the day tank.
2.
Transfer fuel using rotary hand pump.
127(
The hand pump can pump 10 gallons of fuel per minute, approximately 100
revolutions of the handle.
a.
Grasp handle (4).
b.
Turn manual pump handle (4) in clockwise direction to transfer fuel.
3.
While observing the generator control panel fuel gauge (1), fill tank until fuel reaches desired level.
4.
Check for fuel leaks.
PR IM E & R UN
AUX FUEL
M ASTER SW ITCH
O FF
PR IM E
& RUN
START
PREHEAT
2
3
FUEL LEVEL
1
E
F
4