TM 55-1945-205-10-20029 00 20029 00127(Operation of the electric (24VDC) fuel pump is preset to automatically transfer fuel from the base tank to the day tank with the generator control panel master switch. c.Running the generator with the master switch in the PRIME & RUN position (3) will not automatically refuel the day tank.2.Transfer fuel using rotary hand pump.127(The hand pump can pump 10 gallons of fuel per minute, approximately 100 revolutions of the handle.a.Grasp handle (4).b.Turn manual pump handle (4) in clockwise direction to transfer fuel.3.While observing the generator control panel fuel gauge (1), fill tank until fuel reaches desired level.4.Check for fuel leaks.PR IM E & R UN AUX FUELM ASTER SW ITCHO FFPR IM E& RUNSTARTPREHEAT23FUEL LEVEL1EF4