TM 55-1945-205-10-2
0091 00 1/2 blank
0091 00
OPERATOR MAINTENANCE
ROLL-ON/ROLL-OFF DISCHARGE FACILITY
LIGHT TOWER
TROUBLESHOOTING PROCEDURE
INITIAL SETUP:
Personnel Required
Seaman 88K
TROUBLESHOOTING PROCEDURE
ENGINE SHUTS DOWN
SYMPTOM
Engine stops running
MALFUNCTION
Unit out of fuel.
CORRECTIVE ACTION
Check unit fuel level and refuel. (WP 0114 00)
Perform operational check
of light tower. (WP 0034 00)
MALFUNCTION
Engine coolant temperature too high.
CORRECTIVE ACTION
Check the engine coolant level and add as required. (WP 0114 00)
Perform operational check
of light tower. (WP 0034 00)
MALFUNCTION
Engine
oil level
low.
CORRECTIVE ACTION
Check the engine
oil level
and add as required. (WP 0114 00)
Perform operational check of light tower. (WP 0034 00)
MALFUNCTION
Engine
fuel filter
clogged.
CORRECTIVE ACTION
Contact unit maintenance.
END OF WORK PACKAGE
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business