TM 55-1945-205-10-2
0095 00 1
0095 00
OPERATOR MAINTENANCE
ROLL-ON/ROLL-OFF DISCHARGE FACILITY
LIGHT TOWER
TROUBLESHOOTING PROCEDURES
INITIAL SETUP:
Personnel Required
Seaman 88K
TROUBLESHOOTING PROCEDURE
ENGINE HAS NO GENERATOR OUTPUT VOLTAGE
SYMPTOM
No generator output voltage.
MALFUNCTION
Main circuit breaker is in the OFF position.
CORRECTIVE ACTION
Turn the main circuit breaker to the ON position. (WP 0034 00)
Perform operational check of light tower. (WP 0034 00)
MALFUNCTION
Receptacle circuit breaker is in the OFF position.
CORRECTIVE ACTION
Use PUSH TO RESET button to restore the receptacle circuit breaker. (WP 0034 00)
Perform operational check of light tower. (WP 0034 00)
MALFUNCTION
Electrical output overload.
CORRECTIVE ACTION
Reduce electrical output. (WP 0034 00)
Perform operational check of light tower. (WP 0034 00)
MALFUNCTION
Loose wire connections.
CORRECTIVE ACTION
Contact unit maintenance.