TM 55-1945-205-10-20114 00 50114 001 Before .1 Light Tower (Cont’d) 5. Check the electrical controlcompartment for damaged orburned wiring. If wiring is damagedor burned, contact unit maintenance.6. Check for damaged or fadedwarning and caution decals. decalsare damaged or faded, contact unitmaintenance.7. Clear the air ventsof obstructions.8. Check acoustic material on lightset enclosure panels for damage ormissing material. If panels aredamaged or missing, contact unitmaintenance.9. Check for evidence of arcing onelectrical terminals. If arcing isfound, contact unit maintenance.10. Inspect electrical wiring toensure that it is securely connected,clean and undamaged. If wiring isnot securely connected, dirty ordamaged, contact unit maintenance.11. Check all accessible fuseterminal blocks and connections tosee that they are securely connectedand supported, that insulation is notcracked or chafed and that conduitand shielding are secure and ingood condition. If terminal blocksare not securely connected orsupported, insulation is cracked orchafed or shielding is damaged,contact unit maintenance.Table 1. Preventive Maintenance Checks and Services. (Continued)ITEMNO.INTERVALMAN-HOURSITEM TO BECHECKED ORSERVICEDPROCEDUREEQUIPMENTNOT READY/AVAILABLE IF: