TM 55-1945-205-10-20114 00 180114 00WARNINGUse approved procedures when cleaning up fuel spills. Take proper precautionswhen removing or installing any fuel system component. Failure to comply mayresult in serious injury to death to personnel.12 Before .3 Rigid HullInflatable Boat1. Check fuel tank, fuel lines andmotor for evidence of fuel leaks. Iffuel leaks are found, contact unitmaintenance.Any Class I fuelleakage is found.2. Check oil tank and oil lines forevidence of oil leaks. If oil leaks arefound, contact unit maintenance.Any Class III oilleakage is found.3. Check shifting/speed controlhandle for binding and freedomof movement. If binding is found,contact unit maintenance.WARNINGDo not reverse battery polarity. Failure to comply could result in injury or death.4. Inspect battery systemfor damage.Table 1. Preventive Maintenance Checks and Services. (Continued)ITEMNO.INTERVALMAN-HOURSITEM TO BECHECKED ORSERVICEDPROCEDUREEQUIPMENTNOT READY/AVAILABLE IF: