TM 55-1945-205-10-4
0091 00 1
0091 00
OPERATOR MAINTENANCE
FLOATING CAUSEWAY
LIGHT TOWER ENGINE
TROUBLESHOOTING PROCEDURES
INITIAL SETUP:
Personnel Required
Seaman 88K
TROUBLESHOOTING PROCEDURE
FLUCTUATING GENERATOR FREQUENCY/VOLTAGE AND/OR OSCILLATING ENGINE SPEED
SYMPTOM
Fluctuating generator frequency/voltage and/or oscillating engine speed.
MALFUNCTION
Light tower unit is not level.
CORRECTIVE ACTION
Reposition unit so that it is level. (WP 0023 00)
MALFUNCTION
Main circuit breaker is in the OFF position.
CORRECTIVE ACTION
Turn the main circuit breaker to the ON position. (WP 0007 00)
Perform operational check of light tower. (WP 0032 00)
MALFUNCTION
Ambient temperature is greater than 125° Fahrenheit (52° Celsius).
CORRECTIVE ACTION
Do not operate light tower.
MALFUNCTION
There is an electrical output overload.
CORRECTIVE ACTION
Reduce electrical output. (WP 0032 00)
Perform operational check of light tower. (WP 0032 00)