TM 55-1945-205-10-40099 00 120099 003 Before .2 Generator Container(Cont’d)7. Inspect portable fire extinguisherfor discharge nozzle obstruction,proper mounting, tag signed withinthe last month and that all seals andpins are in place. If discharge nozzleobstruction, improper mounting isfound or seals or pins are missing,contact unit maintenance.Fire extinguisher isinoperative.8. Perform PMCS on generator.(TM 9-6115-642-10)4 Before .1 Personnel Shelter 1. Check exterior of containerfor damage. If damage is found,contact unit maintenance.2. Check personnel access door forproper operation. If door does notoperate properly, contact unitmaintenance.3. Check personnel escape scuttleseals and latches for damage. Ifscuttle seals or latches are damaged,contact unit maintenance.4. Inspect portable fire extinguisherfor discharge nozzle obstruction,proper mounting, tag signed withinthe last month and that all seals andpins are in place. If discharge nozzleobstruction or improper mounting isfound or seals or pins are missing,contact unit maintenance.Fire extinguisher isinoperative.5. Check shelter lighting foroperation and burned out bulbs.If lighting does not operate or bulbsare burned out, contact unitmaintenance.6. Check heating and airconditioning system for properoperation. (WP 0029 00) If heatingand air conditioning system does notoperate, contact unit maintenance.Table 1. Preventive Maintenance Checks and Services. (Continued)ITEMNO.INTERVALMAN-HOURSITEM TO BECHECKED ORSERVICEDPROCEDUREEQUIPMENTNOT READY/AVAILABLE IF:
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business