TM 55-1945-205-10-4
0099 00 20
0099 00
8
Before
.5
Offshore Anchor
Mooring System
(Contd)
3. Check lever hoist rachets for
proper operation loose or missing
hardware and corrosion.If corrosion,
damaged or missing hardware is
discovered or ratchet does not
operate properly, contact unit
maintenance.
4. Check anchor stabilizers for
cracks, corrosion and elongated
bolt holes. If cracks, corrosion or
elongated bolts holes are found
contact unit maintenance.
5. Check anchor buoy for punctures
that would affect buoyancy. If
punctures are found contact unit
maintenance.
a. Inspect metallic parts of buoy
for excessive wear, corrosion
and distortion. If excessive wear,
corrosion or distortion are found
contact unit maintenance.
b. Inspect buoy shackle for
excessive wear, corrosion and
distortion. Check to see that
cotter pins are correctly
installed. If excessive wear,
corrosion or distortion is found
or cotter pins are missing or
improperly installed, contact
unit maintenance.
9
Before
.05
Mooring Bitts
Check for cracked, loose or
damaged mooring bitts. If cracks,
loose or damaged mooring bitts are
found contact unit maintenance.
Table 1. Preventive Maintenance Checks and Services. (Continued)
ITEM
NO.
INTERVAL
MAN-
HOURS
ITEM TO BE
CHECKED OR
SERVICED
PROCEDURE
EQUIPMENT
NOT READY/
AVAILABLE IF: