TROUBLESHOOTING PROCEDURE
FAN MOTOR RUNS ON ONE SPEED
SYMPTOM
The fan motor only runs on one speed.
MALFUNCTION
The fan motor switch is defective.
CORRECTIVE ACTION
Replace switch. Contact depot maintenance.
MALFUNCTION
Wires to the fan motor are broken.
CORRECTIVE ACTION
Repair/replace wiring as necessary. (WP 0348 00)
Perform operational check on heating and air conditioning system.
(TM 55-1945-205-10-2)
MALFUNCTION
Fan motor is miswired.
CORRECTIVE ACTION
Replace fan motor. (WP 0108 00)
Perform operational check on heating and air conditioning system.
(TM 55-1945-205-10-2)
MALFUNCTION
Fan motor wiring is grounding out.