INCINERATOR TOILET MALFUNCTIONS - TM-55-1945-205-24-2_141
pump/motor
TM-55-1945-205-24-2 Modular Causeway System (MCS) Roll-On/Roll-Off Discharge Facility Model (RRDF) RRDF-1 NSN 1945-01-473-2282 Manual
Page Navigation
91
92
93
94
95
96
97
98
99
100
101
TM 55-1945-205-24-2
0040 00 1/2 blank
0040 00
UNIT, DIRECT SUPPORT AND GENERAL SUPPORT MAINTENANCE
ROLL-ON/ROLL-OFF DISCHARGE FACILITY
GENERATOR
CONTAINER
TROUBLESHOOTING PROCEDURES
INITIAL SETUP:
Personnel Required
Seaman 88K
References
TM 55-1945-205-10-2
TM 9-6115-642-10
TM 9-6115-643-10
TROUBLESHOOTING PROCEDURE
BASE TANK FUEL LEVEL INDICATION SYSTEM IS INOPERATIVE
SYMPTOM
Base tank fuel level indication system is inoperative.
MALFUNCTION
Fuel level indication system fuse is blown.
CORRECTIVE ACTION
Replace fuse. Contact depot maintenance.
MALFUNCTION
Fuel level sensor inoperable.
CORRECTIVE ACTION
Replace fuel level sensor. (WP 0074 00)
Perform operational check
on fuel level indication system. (TM 55-1945-205-10-2)
MALFUNCTION
System
relay
(s) faulty.
CORRECTIVE ACTION
Replace faulty
relay
(s). (WP 0075 00)
Perform operational check
on fuel level indication system. (TM 55-1945-205-10-2)