TM 55-1945-250-24-20047 00 1/2 blank 0047 00UNIT, DIRECT SUPPORT AND GENERAL SUPPORT MAINTENANCEROLL-ON/ROLL-OFF DISCHARGE FACILITYGENERATOR CONTAINERTROUBLESHOOTING PROCEDURESINITIAL SETUP:Test EquipmentMultimeter, (Item 43, WP 0359 00)Personnel RequiredEngineer 88LReferencesTM 55-1945-205-10-2TM 9-6115-642-10TM 9-6115-643-10TROUBLESHOOTING PROCEDUREELECTRIC FUEL TRANSFER PUMP INOPERATIVESYMPTOMFuel transfer pump is inoperative.MALFUNCTIONNo power to fuel transfer pump.CORRECTIVE ACTIONUsing a multimeter, verify 24 VDC power to the pump. If present, replace pump. (TM 9-6115-642-10, TM 9-6115-643-10)If voltage to the pump is not present, use multimeter to verify continuity of the wiring between the pump and the circuit breaker panel. If continuity is not present, repair/replace wiring as necessary. (WP 0348 00)Perform operational check of electric fuel pump. (TM 55-1945-205-10-2)END OF WORK PACKAGE
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business