TM 55-1945-250-24-2
0048 00 3
0048 00
CORRECTIVE ACTION
Check starter solenoid is receiving power. Connect a multimeter to solenoid output and
ground terminals. Turn the key switch to start and verify voltage to be 12 VDC. If voltage
is verified, replace starter solenoid. (WP 0301 00)
Perform operational check of RHIB engine. (TM 55-1945-205-10-2)
If voltage is not present, check wiring between solenoid and battery for continuity using a
multimeter. If not present, repair/replace wiring as required. Contact depot maintenance
Perform operational check of RHIB engine. (TM 55-1945-205-10-2)
If voltage is present, check wiring between solenoid and ground using a multimeter. If not
present, repair/replace wiring as required. Contact depot maintenance.
If voltage is present, check wiring between solenoid and engine fuse using a multimeter. If
not present, replace wiring as required. Contact depot maintenance.
If voltage is present, check wiring between engine fuse and key start switch using a
multimeter. If not present, replace wiring. Contact depot maintenance.
MALFUNCTION
Faulty key switch.
CORRECTIVE ACTION
Replace the throttle and shift control assembly. (WP 0270 00)
Perform operational check of RHIB engine. (TM 55-1945-205-10-2)
MALFUNCTION
Faulty neutral start switch.
CORRECTIVE ACTION
Replace the throttle and shift control assembly. (WP 0270 00)
Perform operational check of RHIB engine. (TM 55-1945-205-10-2)
MALFUNCTION
Faulty rectifier regulator.
CORRECTIVE ACTION
Replace rectifier regulator. (WP 0302 00)
Perform operational check of RHIB engine. (TM 55-1945-205-10-2)
MALFUNCTION
Faulty stator.