TM 55-1945-205-24-2
0051 00 1
0051 00
UNIT, DIRECT SUPPORT AND GENERAL SUPPORT MAINTENANCE
ROLL-ON/ROLL-OFF DISCHARGE FACILITY
SERVICE UPON RECEIPT OF MATERIEL
INITIAL SETUP:
Personnel Required
Engineer 88L
References
DA PAM 738-750
SF 361
TM 55-1945-205-10-2
GENERAL INFORMATION
This work package shall contain information required for the user to ensure that the equipment will be adequately
inspected, serviced and operationally tested before it is subjected to use.
CHECK UNPACKED EQUIPMENT
Table 1. Inspection Criteria for Packaging.
COMPONENT
ACCEPTABLE
REPARABLE
NONREPARABLE
Dunnage Matt ISO Container
Exterior
Minor rust, cracks,
indentations, or splits that
would not impair water
proofing or serviceability
of containers.
Dents or bending that does
not affect access door
operation.
Damage or bending that
will not allow doors
to open.
Interior
Items within the container
have remained in stowed
position. No broken,
dented, or cracked
equipment.
Broken or missing
hardware or handles.
Damage to pallets that
would prevent storage of
dunnage matts.
Hardware
Hardware is operative
and tight.
Hardware is inoperative or
loose.
None.
EASY Container
Exterior
Minor rust, cracks,
indentations, or splits that
would not impair water
proofing or serviceability
of containers.
Dents or bending that does
not affect access door
operation.
Damage or bending that
will not allow doors
to open.
Interior
Items within the container
have remained in stowed
position. No broken,
dented, or cracked
equipment.
Leaking hydraulic system.
Inoperative hydraulic
pumps and cylinders.
Minor damage to interior of
container that does not
affect operation.
Bent EASY launch frame
that would affect operation.
Bent or sprung anchor
drawer that would prevent
operation of anchor system.