TM 55-1945-205-24-2
0056 00 2
0056 00
WARNING
2.
Using crane, attach a sling (3) to the lifting shackles (4) on the module (2) and tilt module to the side where the
machine plug opening (5) is at its lowest point.
3.
Using breaker bar, socket and allen wrench, remove machine plug (1). If water is present, allow to drain.
4.
If water is found, pressure test the intermediate section non-powered module (2). (WP 0057 00)
WARNING
5.
Apply antiseize compound to threads of machine plug (1).
6.
Using breaker bar, socket and allen wrench, install plug (1) into module (2) and tighten.
END OF WORK PACKAGE