TM 55-1945-205-24-20056 00 20056 00WARNING2.Using crane, attach a sling (3) to the lifting shackles (4) on the module (2) and tilt module to the side where the machine plug opening (5) is at its lowest point.3.Using breaker bar, socket and allen wrench, remove machine plug (1). If water is present, allow to drain.4.If water is found, pressure test the intermediate section non-powered module (2). (WP 0057 00)WARNING5.Apply antiseize compound to threads of machine plug (1).6.Using breaker bar, socket and allen wrench, install plug (1) into module (2) and tighten.END OF WORK PACKAGE