TM 55-1945-205-24-2
0080 00 1
0080 00
UNIT LEVEL MAINTENANCE
ROLL-ON/ROLL-OFF DISCHARGE FACILITY
GENERATOR CONTAINER COOLING DAMPER AND MOTOR
REPLACEMENT
INITIAL SETUP:
Tools
Tool Kit, General Mechanics (Rail and Marine) (Item 82, WP 0359 00)
Personnel Required
Engineer 88L
References
TM 55-1945-205-10-2
Equipment Condition
Generator Shut Down. (TM 9-6115-642-10, TM 9-6115-643-10)
REMOVE GENERATOR CONTAINER COOLING DAMPER AND MOTOR
NOTE
The following procedure is typical for the removal and installation of all generator container
cooling dampers and motors.
1.
Remove two screws (1) from louver motor cover (2).
2.
Remove louver motor cover (2) from louver motor (3).
3.
Tag and disconnect wires (4) from louver motor (3).
4.
Remove conduit nut (5) from conduit (6).
5.
Remove twelve lock nuts (7), washers (8) and bolts (9) from louver (10).
7
8
9
2
1
3
5
10
11
6
4