TM 55-1945-205-24-20080 00 10080 00UNIT LEVEL MAINTENANCEROLL-ON/ROLL-OFF DISCHARGE FACILITYGENERATOR CONTAINER COOLING DAMPER AND MOTORREPLACEMENTINITIAL SETUP:ToolsTool Kit, General Mechanic’s (Rail and Marine) (Item 82, WP 0359 00)Personnel RequiredEngineer 88LReferencesTM 55-1945-205-10-2Equipment ConditionGenerator Shut Down. (TM 9-6115-642-10, TM 9-6115-643-10)REMOVE GENERATOR CONTAINER COOLING DAMPER AND MOTORNOTEThe following procedure is typical for the removal and installation of all generator container cooling dampers and motors.1.Remove two screws (1) from louver motor cover (2).2.Remove louver motor cover (2) from louver motor (3).3.Tag and disconnect wires (4) from louver motor (3).4.Remove conduit nut (5) from conduit (6).5.Remove twelve lock nuts (7), washers (8) and bolts (9) from louver (10).7892135101164