Home
Download PDF
Order CD-ROM
Order in Print
INSTALL HEATING AND AIR CONDITIONING SYSTEM FAN MOTOR (cont)
CLEAN HEATING AND AIR CONDITIONING SYSTEM CONDENSER AND COIL FINS - TM-55-1945-205-24-2_334
TM-55-1945-205-24-2 Modular Causeway System (MCS) Roll-On/Roll-Off Discharge Facility Model (RRDF) RRDF-1 NSN 1945-01-473-2282 Manual
Page Navigation
256
257
258
259
260
261
262
263
264
265
266
TM 55-1945-205-24-2
0109 00 1
0109 00
DIRECT SUPPORT MAINTENANCE
ROLL-ON/ROLL-OFF DISCHARGE FACILITY
HEATING AND
AIR CONDITIONING
SYSTEM CONDENSER AND COIL FINS
CLEANING AND INSPECTION
INITIAL SETUP:
Tools
Tool Kit, General Mechanic’s (Item 81, WP 0359 00)
Gloves, Chemical (Item 25, WP 0359 00)
Goggles, Industrial (Chipping, Chemical) (Item 28, WP 0359 00)
Apron, Utility (Item 2, WP 0359 00)
Respirator, Air Filtering (Item 59, WP 0359 00)
Pan, Drain (Item 46, WP 0359 00)
Sprayer, Pesticide (Manually Carried) (Item 71, WP 0359 00)
Brush, Stencil (Soft Bristle) (Item 9, WP 0359 00)
Materials/Parts
Cleaner, Condenser Coil (Item 10, WP 0358 00)
Spill Clean-Up Kit, Hazardous Material (Item 50, WP 0358 00)
Personnel Required
Utilities Equipment Repairer 52C (2)
Equipment Condition
Heating and Air Conditioning System Side Angles Removed. (WP 0103 00)
CLEAN HEATING AND
AIR CONDITIONING
SYSTEM CONDENSER AND COIL FINS
1.
Remove two screws (1) from partition (2).
2.
Remove screw (3) from gusset (4).
3.
Remove gusset (4).
3
2
4
1