Home
Download PDF
Order CD-ROM
Order in Print
TEST LIGHT TOWER ENGINE GLOW PLUGS - TM-55-1945-205-24-2_408
SERVICE LIGHT TOWER BATTERY - TM-55-1945-205-24-2_410
TM-55-1945-205-24-2 Modular Causeway System (MCS) Roll-On/Roll-Off Discharge Facility Model (RRDF) RRDF-1 NSN 1945-01-473-2282 Manual
Page Navigation
325
326
327
328
329
330
331
332
333
334
335
TM 55-1945-205-24-2
0141 00 1
0141 00
UNIT LEVEL MAINTENANCE
ROLL-ON/ROLL-OFF DISCHARGE FACILITY
LIGHT TOWER BATTERY
SERVICING AND INSPECTION
INITIAL SETUP:
Tools
Tool Kit, General Mechanic’s (Rail and Marine) (Item 82, WP 0359 00)
Gloves, Men’s and Women’s (Leather Palm) (Item 27, WP 0359 00)
Goggles, Sun, Wind and Dust (Safety) (Item 29, WP 0359 00)
Helmet, Safety (Brown) (Item 33, WP 0359 00)
Life Preserver, Vest (Item 38, WP 0359 00)
Gloves, Chemical (Item 25, WP 0359 00)
Goggles, Industrial (Chipping, Chemical) (Item 28, WP 0359 00)
Respirator, Air Filtering (Item 59, WP 0359 00)
Brush, Stencil (Soft Bristle) (Item 9, WP 0359 00)
Materials/Parts
Rag, Wiping (Item 45, WP 0358 00)
Water, Reagent Distilled (Item 60, WP 0358 00)
Personnel Required
Engineer 88L
Equipment Condition
Light Tower Battery Negative Lead Terminal Removed. (WP 0134 00)
SERVICE LIGHT TOWER BATTERY
WARNING
All personnel must wear personal flotation device, hard hat, safety shoes and gloves
during RRDF operations and maintenance. Failure to observe these precautions
could result in serious injury or death.
CAUTION
Ensure only distilled water is added when levels drop below acceptable limits.
Failure to comply could result in equipment damage.
1.
Remove battery caps (1) covering the water reservoirs of battery (2).
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business