TM 55-1945-205-24-20155 00 10155 00DIRECT SUPPORT MAINTENANCEROLL-ON/ROLL-OFF DISCHARGE FACILITYLIGHT TOWER SHUTDOWN SOLENOIDREPLACEMENTINITIAL SETUP:ToolsTool Kit, General Mechanic’s (Item 81, WP 0359 00)Gloves, Men’s and Women’s (Leather Palm) (Item 27, WP 0359 00)Goggles, Sun, Wind and Dust (Safety) (Item 29, WP 0359 00) Helmet, Safety (Brown) (Item 33, WP 0359 00)Life Preserver, Vest (Item 38, WP 0359 00)Materials/PartsSolenoid, Shutdown(33968)PN 36878189Personnel RequiredEngineer 88LReferencesTM 55-1945-205-10-2Equipment ConditionLight Tower Battery Negative Lead Terminal Removed. (WP 0134 00)REMOVE LIGHT TOWER SHUTDOWN SOLENOIDWARNINGAll personnel must wear personal flotation device, hard hat, safety shoes and gloves during RRDF operations and maintenance. Failure to observe these precautions could result in serious injury or death.1.Tag and disconnect electrical plug (1) supplying power to shutdown solenoid (2), located on forward starboard side of light tower engine.