INSTALL THE LIGHT TOWER BULBS
REMOVE LIGHT TOWER OPTICAL/SOCKET ASSEMBLY - TM-55-1945-205-24-2_464
TM-55-1945-205-24-2 Modular Causeway System (MCS) Roll-On/Roll-Off Discharge Facility Model (RRDF) RRDF-1 NSN 1945-01-473-2282 Manual
Page Navigation
368
369
370
371
372
373
374
375
376
377
378
TM 55-1945-205-24-2
0157 00 1
0157 00
DIRECT SUPPORT MAINTENANCE
ROLL-ON/ROLL-OFF DISCHARGE FACILITY
LIGHT TOWER OPTICAL/SOCKET ASSEMBLY
REMOVAL AND INSTALLATION
INITIAL SETUP:
Tools
Tool Kit, General Mechanic’s (Item 81, WP 0359 00)
Gloves, Men’s and Women’s (Leather Palm) (Item 27, WP 0359 00)
Goggles, Sun, Wind and Dust (Safety) (Item 29, WP 0359 00)
Helmet, Safety (Brown) (Item 33, WP 0359 00)
Life Preserver, Vest (Item 38, WP 0359 00)
Materials/Parts
Optical/Socket Assembly
(33968)
PN 36885226
Personnel Required
Engineer 88L
References
TM 55-1945-205-10-2
Equipment Condition
Light Tower Battery Negative Terminal Lead Removed. (WP 0134 00)
REMOVE LIGHT TOWER OPTICAL/SOCKET ASSEMBLY
WARNING
All personnel must wear personal flotation device, hard hat, safety shoes and gloves
during RRDF operations and maintenance. Failure to observe these precautions
could result in serious injury or death.
1.
Loosen eye bolt (1).
2
1
3
4
5