INSTALL LIGHT TOWER OPTICAL/SOCKET ASSEMBLY
WARNING
1.
Position optical/socket assembly (10) on trunnion (11).
2.
Install bolt (9) and nut (8) and tighten nut (8).
3.
Connect cord (6) to receptacle (7).
4.
Remove lock pin (5) to secure tower in lowered position.
5.
Operate winch (4) to raise tower.
6.
Insert and lock pin (3) to secure tower in the raised position.
NOTE
Do not extend mast tower past upright mark on tower.
7.
With tower in upright position, operate winch (2) to extend tower to 28 ft above collar. Do not extend past upright
mark on tower.
8.
Loosen eye bolt (1) to rotate tower.
9.
Tighten eye bolt (1) after rotating tower.
10. Install light tower battery negative lead terminal. (WP 0134 00)
11. Perform operational check of light tower. (TM 55-1945-205-10-2)
END OF WORK PACKAGE