0016 00 2
0016 00
CORRECTIVE ACTION
Drain fuel filter bowl. (WP 0167 00)
Replace fuel
filter element
. (WP 0168 00)
Replace in line
fuel filter
. (WP 0171 00)
Perform operational check of light tower engine. (TM 55-1945-205-10-2)
MALFUNCTION
Engine air filter element is dirty.
CORRECTIVE ACTION
Clean engine air
filter element
. (WP 0175 00)
Perform operational check
of light tower engine. (TM 55-1945-205-10-2)
MALFUNCTION
Loose wire conditions.
CORRECTIVE ACTION
Check for loose wire connections and tighten as required.
Perform operational check
of light tower engine. (TM 55-1945-205-10-2)
MALFUNCTION
Engine speed oscillating during operation.
CORRECTIVE ACTION
Adjust engine speed as required. Contact depot maintenance.
MALFUNCTION
Engine power is low.
CORRECTIVE ACTION
Adjust engine power as required. Contact depot maintenance.
MALFUNCTION
Generator
is defective.
CORRECTIVE ACTION
Replace defective
generator
. Contact depot maintenance.
END OF WORK PACKAGE