TM 55-1945-205-24-2
0017 00 2
0017 00
MALFUNCTION
Battery is not properly charged.
CORRECTIVE ACTION
Charge battery or replace as required. (WP 0141 00, WP 0142 00)
Perform operational check
of light tower engine. (TM 55-1945-205-10-2)
MALFUNCTION
Fuel injection nozzle has carbon build-up.
CORRECTIVE ACTION
Clean or replace
fuel injection
nozzle. Contact depot maintenance.
MALFUNCTION
Fuel injection nozzle functioning improperly.
CORRECTIVE ACTION
Replace fuel injection nozzle. Contact depot maintenance.
MALFUNCTION
Valve clearance is not adjusted properly.
CORRECTIVE ACTION
Adjust valve(s) to proper clearance. Contact depot maintenance.
MALFUNCTION
Engine has
low compression
.
CORRECTIVE ACTION
Replace internal parts as required. Contact depot maintenance.
MALFUNCTION
Valve(s) are leaking.
CORRECTIVE ACTION
Clean and grind valve(s) as required. Contact depot maintenance.
MALFUNCTION
Fuel injection timing not properly adjusted.
CORRECTIVE ACTION
Adjust
fuel injection
timing as required. Contact depot maintenance.
END OF WORK PACKAGE