TM 55-1945-205-24-20305 00 40305 00{7} With both tachometer (16) and VRO pump (12) disconnected, verify increase of two volts.{8} If increase is more than two volts, rectifier/regulator (11) is faulty.12. Disconnect multimeter and shut down RHIB engine. (TM 55-1945-205-10-2)13. Connect tachometer (16) to dash terminal strip (5).14. Connect VRO pump (12) to engine terminal strip (10).15. Position key switch to on but do start engine.16. Connect multimeter to the engine terminal strip purple lead (17) and engine ground (19).17. Verify voltage reading.a.If battery voltage is present, rectifier/regulator (11) is faulty.b.If no voltage is present, test starter circuit (WP 0048 00), and instrument wiring harness (15).18. Disconnect multimeter.19. Position key switch to off.20. Remove engine from test tank.21. Install the primer solenoid bottom mounting clamp screw (1), ground lock washer (2) and ground wire (3) on the mounting clamp (4).22. Install RHIB engine cover. (WP 0297 00)23. Install RHIB battery negative lead terminal. (WP 0336 00)END OF WORK PACKAGE
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business