LIGHT TOWER - TM-55-1945-205-24-4_103
Thermostat is defective.
TM-55-1945-205-24-4 Modular Causeway System (MCS) Floating Causeway FC-1 NSN 1945-01-473-2162 Manual
Page Navigation
64
65
66
67
68
69
70
71
72
73
74
TM 55-1945-205-24-4
0022 00 2
0022 00
CORRECTIVE ACTION
Flush
cooling system
. (WP 0176 00)
Perform operational check of light tower engine. (TM 55-1945-205-10-4)
MALFUNCTION
Engine radiator is defective.
CORRECTIVE ACTION
Replace engine radiator. (WP 0184 00)
Perform operational check
of light tower engine. (TM 55-1945-205-10-4)
MALFUNCTION
Engine is leaking water.
CORRECTIVE ACTION
Ensure radiator drain cocks are securely closed. (TM 55-1945-205-10-4)
Check cooling hoses and fittings. Replace as necessary. (WP 0177 00, WP 0178 00)
Check radiator for punctures. Replace as necessary. (WP 0184 00)
Perform operational check of light tower engine. (TM 55-1945-205-10-4)
MALFUNCTION
Fan belt is loose or broken.
CORRECTIVE ACTION
Tighten or replace fan belt. (WP 0180 00)
Perform operational check of light tower engine. (TM 55-1945-205-10-4)
MALFUNCTION
Fan is defective.
CORRECTIVE ACTION
Replace defective fan. (WP 0181 00)
Perform operational check
of light tower engine. (TM 55-1945-205-10-4)