TM 55-1945-205-24-4
0023 00 1
0023 00
UNIT, DIRECT SUPPORT AND GENERAL SUPPORT MAINTENANCE
FLOATING CAUSEWAY
VHF/FM TRANSCEIVER
TROUBLESHOOTING PROCEDURES
INITIAL SETUP:
Personnel Required
Seaman 88K
References
TM 55-1945-205-10-4
TROUBLESHOOTING PROCEDURE
VHF/FM TRANSCEIVER HAS NO POWER
SYMPTOM
Transceiver has no power.
MALFUNCTION
Transceiver batteries are discharged.
CORRECTIVE ACTION
Charge the batteries. (TM 55-1945-205-10-4)
Perform operational test on transceiver. (TM 55-1945-205-10-4)
MALFUNCTION
Transceiver battery charger is defective.
CORRECTIVE ACTION
Replace battery charger. (WP 0129 00)
Perform operational test on transceiver. (TM 55-1945-205-10-4)
MALFUNCTION
Transceiver battery charger power supply is defective.
CORRECTIVE ACTION
Replace battery charger power supply. (WP 0130 00)
Perform operational test on transceiver. (TM 55-1945-205-10-4)