TM 55-1945-205-24-40034 00 20034 00MALFUNCTIONFan motor is wired incorrectly.CORRECTIVE ACTIONReplace fan motor. (WP 0105 00)Perform operational check on heating and air conditioning system. (TM 55-1945-205-10-4)MALFUNCTIONFan motor winding is grounding out.CORRECTIVE ACTIONReplace fan motor. (WP 0105 00)Perform operational check on heating and air conditioning system. (TM 55-1945-205-10-4)MALFUNCTIONFan motor winding has an open condition.CORRECTIVE ACTIONReplace fan motor. (WP 0105 00)Perform operational check on heating and air conditioning system. (TM 55-1945-205-10-4)MALFUNCTIONFan motor has a defective capacitor.CORRECTIVE ACTIONReplace fan motor. (WP 0105 00)Perform operational check on heating and air conditioning system. (TM 55-1945-205-10-4)MALFUNCTIONFan blade is stuck or damaged.CORRECTIVE ACTIONFree fan blade and replace as required. (WP 0105 00)Perform operational check on heating and air conditioning system. (TM 55-1945-205-10-4)