TM 55-1945-205-24-4
0035 00 2
0035 00
MALFUNCTION
Fan motor switch is defective.
CORRECTIVE ACTION
Replace switch. Contact depot maintenance.
MALFUNCTION
Wiring to fan motor is broken.
CORRECTIVE ACTION
Using multimeter, check continuity of the wiring to fan motor. If continuity is not present,
repair/replace wiring as necessary. (WP 0246 00, WP 0248 00)
Perform operational check on heating and air conditioning system.
(TM 55-1945-205-10-4)
MALFUNCTION
Fan motor is wired incorrectly.
CORRECTIVE ACTION
Replace fan motor. (WP 0105 00)
Perform operational check on heating and air conditioning system.
(TM 55-1945-205-10-4)
MALFUNCTION
Fan motor winding is grounding out.
CORRECTIVE ACTION
Replace fan motor. (WP 0105 00)
Perform operational check on heating and air conditioning system.
(TM 55-1945-205-10-4)
MALFUNCTION
Fan motor winder has an open condition.
CORRECTIVE ACTION
Replace fan motor. (WP 0105 00)
Perform operational check on heating and air conditioning system.
(TM 55-1945-205-10-4)
END OF WORK PACKAGE