TM 55-1945-205-24-40035 00 20035 00MALFUNCTIONFan motor switch is defective.CORRECTIVE ACTIONReplace switch. Contact depot maintenance.MALFUNCTIONWiring to fan motor is broken. CORRECTIVE ACTIONUsing multimeter, check continuity of the wiring to fan motor. If continuity is not present, repair/replace wiring as necessary. (WP 0246 00, WP 0248 00)Perform operational check on heating and air conditioning system. (TM 55-1945-205-10-4)MALFUNCTIONFan motor is wired incorrectly.CORRECTIVE ACTIONReplace fan motor. (WP 0105 00)Perform operational check on heating and air conditioning system. (TM 55-1945-205-10-4)MALFUNCTIONFan motor winding is grounding out.CORRECTIVE ACTIONReplace fan motor. (WP 0105 00)Perform operational check on heating and air conditioning system. (TM 55-1945-205-10-4)MALFUNCTIONFan motor winder has an open condition.CORRECTIVE ACTIONReplace fan motor. (WP 0105 00)Perform operational check on heating and air conditioning system. (TM 55-1945-205-10-4)END OF WORK PACKAGE