TM 55-1945-205-24-40038 00 10038 00UNIT, DIRECT SUPPORT AND GENERAL SUPPORT MAINTENANCEFLOATING CAUSEWAYHEATING AND AIR CONDITIONING SYSTEMTROUBLESHOOTING PROCEDURESINITIAL SETUP:Personnel RequiredEngineer 88LReferencesTM 55-1945-205-10-4TROUBLESHOOTING PROCEDUREFAN MOTOR RUNS ON ONE SPEED SYMPTOMThe fan motor only runs on one speed.MALFUNCTIONThe fan motor switch is defective.CORRECTIVE ACTIONReplace switch. Contact depot maintenance.MALFUNCTIONWires to the fan motor are broken.CORRECTIVE ACTIONRepair/replace wiring as necessary. (WP 0246 00, WP 0248 00)Perform operational check on heating and air conditioning system. (TM 55-1945-205-10-4)MALFUNCTIONFan motor is miswired.CORRECTIVE ACTIONReplace fan motor. (WP 0105 00)Perform operational check on heating and air conditioning system. (TM 55-1945-205-10-4)