TM 55-1945-205-24-40050 00 20050 00Table 1. Preventive Maintenance Checks and Services.ITEMNO.INTERVALMAN-HOURSITEM TO BECHECKED ORSERVICEDPROCEDUREEQUIPMENTNOT READY/AVAILABLE IF:1Monthly.2Personnel Shelter1. Clean heating and air conditioning system indoor air filter.(WP 0097 00)2. Clean heating and air conditioning system vent air filter.(WP 0099 00)4Quarterly29.0FC ModulesInspect for water inside all modules. (WP 0053 00) (WP 0059 00)2Quarterly100 Hours.1Light Tower Quarterly or every 100 operating hours replace the fuel tank in-line fuel filter. (WP 0168 00)1Annually.2Personnel ShelterClean heating and air conditioningsystem internal components.(WP 0102 00, WP 0103 00, WP 0106 00)3Annually.2Light Tower Engine1. Replace air filter element. (WP 0172 00) 2. Perform functional test of engine oil pressure switch in the protection shutdown system. Contact depot maintenance. Contact Specialized Repair Activity (SRA).4Annually2,400 Operating Hours1.0FC ModulesAnnually or every 2,400 hours of operation, pressure test modules and repair leaks, cracks and corrosion.(WP 0054 00, WP 0060 00)Leaks present or structural damage which interferes with operation. 3Biennially3.0Light Tower Engine1. Drain cooling system, flush cooling system and install new coolant.(WP 0175 00, WP 0176 00)2. Replace all coolant hoses and clamps.(WP 0177 00, WP 0178 00)3. Replace all fuel hosesand clamps. Contact Specialized Repair Activity (SRA).4. Replace battery. (WP 0139 00)350 Operating Hours.2Light Tower Engine1. After the first 50 hours of operation, change the engine oil. (WP 0162 00)