3
50 Operating
Hours
.2
Light Tower Engine
(Cont’d)
2. After the first 50 hours of
operation, replace the engine oil
filter. (WP 0163 00)
3
100
Operating
Hours
.5
Light Tower Engine
Remove and clean air
filter element
.
(WP 0172 00)
3
200
Operating
Hours
.5
Light Tower Engine
Change engine oil. (WP 0162 00)
3
250
Operating
Hours
.3
Light Tower Engine
Repack wheel
bearings
and replace
grease seals. (WP 0191 00)
3
400
Operating
Hours
.3
Light Tower Engine
1. Replace engine oil filter.
(WP 0163 00)
2. Replace engine
fuel filter
.
(WP 0165 00)
3
500
Operating
Hours
3.0
Light Tower Engine
1. Drain
cooling system
, flush
cooling system
and install new
coolant. (WP 0175 00, WP 0176 00)
2. Replace fan belt. (WP 0180 00)
Table 1. Preventive Maintenance Checks and Services. (Continued)
ITEM
NO.
INTERVAL
MAN-
HOURS
ITEM TO BE
CHECKED OR
SERVICED
PROCEDURE
EQUIPMENT
NOT READY/
AVAILABLE IF:
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business