TM 55-1945-205-24-40067 00 10067 00UNIT LEVEL MAINTENANCEFLOATING CAUSEWAYGENERATOR CONTAINER SHORE TIE PENETRATION HINGED COVERREPLACEMENTINITIAL SETUP:ToolsTool Kit, General Mechanic’s (Rail and Marine) (Item 54, WP 0253 00)Gloves, Men’s and Women’s (Leather Palm) (Item 16, WP 0253 00)Goggles, Sun, Wind and Dust (Safety) (Item 18, WP 0253 00) Helmet, Safety (Brown) (Item 20, WP 0253 00)Life Preserver, Vest (Item 25, WP 0253 00)Materials/PartsCover, Access (81340)PN MCSFC-99-310-001-104Personnel RequiredEngineer 88LREMOVE GENERATOR CONTAINER SHORE TIE PENETRATION HINGED COVERWARNINGAll personnel must wear personal flotation device, hard hat, safety shoes and gloves during FC operations and maintenance. Failure to observe these precautions could result in serious injury or death.1.Remove five cover hinge screws (1) securing cover (2) to the generator container exterior wall (3).2.Remove cover (2) and discard.213