TM 55-1945-205-24-4
0068 00 3/4 blank
0068 00
7.
Pull generator container shore tie female connector (2) outward from shore tie recess pocket (12).
8.
Loosen four screws (13) on back of generator container shore tie female connector (2).
9.
Tag and remove wires (14) from generator container shore tie female connector (2).
10. Remove generator container shore tie female connector (2) and discard.
INSTALL GENERATOR CONTAINER SHORE TIE FEMALE ELECTRICAL CONNECTOR
1.
Install wires (14) in new generator container shore tie female connector (2) and remove tags.
2.
Tighten four screws (13) on back of generator container shore tie female connector (2).
3.
Position generator container shore tie female connector (2) in shore tie recess pocket (12).
4.
Install four plastic washers (11) and screws (10) in generator container shore tie female connector (2) and tighten.
5.
Slide the stuffing tube packing (9) and plastic packing washers (8) into nylon stuffing tube (7).
6.
Slide stuffing tube packing retainer cap (6) onto nylon stuffing tube (7).
7.
Rotate stuffing tube packing retainer cap (6) clockwise and tighten.
8.
Position generator container shore tie junction box cover (4) on junction box (5), install two screws (3) and tighten.
9.
Perform operational check of generator. (TM 55-1945-205-10-4)
END OF WORK PACKAGE